product description | |||||||
Product Image | |||||||
Product number | UPT-1.5 | UPT-1.5/2 | UPT-1.5/2L | UPT-1.5/1-2 | UPT-1.5/2-2 | UPT-1.5/3 | UPT-1.5/3L |
product type |
Rail wiring distribution block |
Rail wiring distribution block |
Rail wiring distribution block |
Rail wiring distribution block |
Rail wiring distribution block |
Rail wiring distribution block |
Rail wiring distribution block |
Mechanical structure |
Push-in spring connection |
Push-in spring connection |
Push-in spring connection |
Push-in spring connection |
Push-in spring connection |
Push-in spring connection |
Push-in spring connection |
layers |
1 |
2 |
2 |
1 |
1 |
3 |
3 |
Electric potential |
1 |
2 |
1 |
1 |
1 |
3 |
1 |
connection volume |
2 |
4 |
4 |
3 |
4 |
6 |
6 |
Rated cross section |
1.5mm2 |
1.5mm2 |
1.5mm2 |
1.5mm2 |
1.5mm2 |
1.5mm2 |
1.5mm2 |
Rated current |
17.5A |
16A |
16A |
17.5A |
17.5A |
15A |
15A |
Rated voltage |
300V |
300V |
300V |
300V |
300V |
300V |
300V |
Open side panel |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Grounding feet |
no |
no |
no |
no |
no |
no |
no |
other |
The connecting rail needs to install the rail foot F-NS35 |
The connecting rail needs to install the rail foot F-NS35 |
The connecting rail needs to install the rail foot F-NS35 |
The connecting rail needs to install the rail foot F-NS35 |
The connecting rail needs to install the rail foot F-NS35 |
The connecting rail needs to install the rail foot F-NS35 |
The connecting rail needs to install the rail foot F-NS35 |
Application field |
Widely used in electrical connection, industrial |
Widely used in electrical connection, industrial |
Widely used in electrical connection, industrial |
Widely used in electrical connection, industrial |
Widely used in electrical connection, industrial |
Widely used in electrical connection, industrial |
Widely used in electrical connection, industrial |
color |
(gray)、(dark gray)、(green)、(yellow)、(cream)、(orange)、(black)、(red)、(blue)、(white)、(purple)、(Brown)、customizable |
(gray)、(dark gray)、(green)、(yellow)、(cream)、(orange)、(black)、(red)、(blue)、(white)、(purple)、(Brown)、customizable |
(gray)、(dark gray)、(green)、(yellow)、(cream)、(orange)、(black)、(red)、(blue)、(white)、(purple)、(Brown)、customizable |
(gray)、(dark gray)、(green)、(yellow)、(cream)、(orange)、(black)、(red)、(blue)、(white)、(purple)、(Brown)、customizable |
(gray)、(dark gray)、(green)、(yellow)、(cream)、(orange)、(black)、(red)、(blue)、(white)、(purple)、(Brown)、customizable |
(gray)、(dark gray)、(green)、(yellow)、(cream)、(orange)、(black)、(red)、(blue)、(white)、(purple)、(Brown)、customizable |
(gray)、(dark gray)、(green)、(yellow)、(cream)、(orange)、(black)、(red)、(blue)、(white)、(purple)、(Brown)、customizable |
Details parameters: | |||||||
Wiring data | |||||||
line contact | |||||||
Stripping length |
8mm — 10mm |
8mm — 10mm |
8mm — 10mm |
8mm — 10mm |
8mm — 10mm |
8mm — 10mm |
8mm — 10mm |
Rigid Conductor Cross Section |
0.2mm² -1.5mm² |
0.2mm² -1.5mm² |
0.2mm² -1.5mm² |
0.2mm² -1.5mm² |
0.2mm² -1.5mm² |
0.2mm² -1.5mm² |
0.2mm² -1.5mm² |
Flexible conductor cross section |
0.2mm² -1.5mm² |
0.2mm² -1.5mm² |
0.2mm² -1.5mm² |
0.2mm² -1.5mm² |
0.2mm² -1.5mm² |
0.2mm² -1.5mm² |
0.2mm² -1.5mm² |
Rigid Conductor Cross Section AWG |
26-14 |
26-14 |
26-14 |
26-14 |
26-14 |
26-14 |
26-14 |
Flexible Conductor Cross Section AWG |
26-14 |
26-14 |
26-14 |
26-14 |
26-14 |
26-14 |
26-14 |
Size (this is the dimension of the UPT-2.5 carrying rail foot F-NS35 installed on the rail) | |||||||
Thickness |
3.5mm |
3.5mm |
3.5mm |
3.5mm |
3.5mm |
3.5mm |
3.5mm |
Width |
45mm |
65.4mm |
65.4mm |
54mm |
63.2mm |
97.25mm |
97.25mm |
Height |
30.5mm |
41.1mm |
41.1mm |
30.5mm |
30.5mm |
51.7mm |
51.7mm |
NS35/7.5 high |
38mm |
48.6mm |
48.6mm |
38mm |
38mm |
59.2mm |
59.2mm |
NS35/15 high |
53mm |
56.1mm |
56.1mm |
53mm |
53mm |
66.7mm |
66.7mm |
NS15/5.5 high |
36mm |
46.6mm |
46.6mm |
36mm |
36mm |
57.2mm |
57.2mm |
Material properties | |||||||
Flame retardant grade, in line with UL94 |
V0 |
V0 |
V0 |
V0 |
V0 |
V0 |
V0 |
Insulation Materials |
PA |
PA |
PA |
PA |
PA |
PA |
PA |
Insulation material group |
I |
I |
I |
I |
I |
I |
I |
IEC IEC Electrical parameters | |||||||
standard test |
IEC 60947-7-1 |
IEC 60947-7-1 |
IEC 60947-7-1 |
IEC 60947-7-1 |
IEC 60947-7-1 |
IEC 60947-7-1 |
IEC 60947-7-1 |
Rated voltage(III/3) |
300V |
300V |
300V |
300V |
300V |
300V |
300V |
Rated current(III/3) |
17.5A |
16A |
16A |
17.5A |
17.5A |
15A |
15A |
Rated surge voltage |
8kv |
8kv |
8kv |
8kv |
8kv |
6kv |
6kv |
Overvoltage class |
III |
III |
III |
III |
III |
III |
III |
pollution level |
3 |
3 |
3 |
3 |
3 |
3 |
3 |
Electrical performance test | |||||||
Surge Voltage Test Results |
Passed the test |
Passed the test |
Passed the test |
Passed the test |
Passed the test |
Passed the test |
Passed the test |
Power frequency withstand voltage test results |
Passed the test |
Passed the test |
Passed the test |
Passed the test |
Passed the test |
Passed the test |
Passed the test |
Temperature rise test results |
Passed the test |
Passed the test |
Passed the test |
Passed the test |
Passed the test |
Passed the test |
Passed the test |
Environmental conditions | |||||||
Ambient temperature (operating) |
-60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) |
-60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) |
-60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) |
-60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) |
-60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) |
-60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) |
-60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) |
Ambient temperature (storage/transport) |
-25 °C- 60 °C (short term (up to 24 hours), -60 °C to +70 °C) |
-25 °C - 60 °C (short term (up to 24 hours), -60 °C to +70 °C) |
-25 °C -60 °C (short term (up to 24 hours), -60 °C to +70 °C) |
-25 °C -60 °C (short term (up to 24 hours), -60 °C to +70 °C) |
-25 °C-60 °C (short term (up to 24 hours), -60 °C to +70 °C) |
-25 °C-60 °C (short term (up to 24 hours), -60 °C to +70 °C) |
-25 °C-60 °C (short term (up to 24 hours), -60 °C to +70 °C) |
Ambient temperature (assembled) |
-5 °C-70 °C |
-5 °C -70 °C |
-5 °C-70 °C |
-5 °C -70 °C |
-5 °C-70 °C |
-5 °C-70 °C |
-5 °C-70 °C |
Ambient temperature (execution) |
-5 °C-70 °C |
-5 °C -70 °C |
-5 °C-70 °C |
-5 °C -70 °C |
-5 °C-70 °C |
-5 °C-70 °C |
-5 °C-70 °C |
Relative Humidity (Storage/Transportation) |
30 % — 70 % |
30 % — 70 % |
30 % — 70 % |
30 % — 70 % |
30 % — 70 % |
30 % — 70 % |
30 % — 70 % |
Environmental friendly | |||||||
RoHS |
No excessive harmful substances |
No excessive harmful substances |
No excessive harmful substances |
No excessive harmful substances |
No excessive harmful substances |
No excessive harmful substances |
No excessive harmful substances |
Standards and Specifications | |||||||
Connections are standard |
IEC 60947-7-1 |
IEC 60947-7-1 |
IEC 60947-7-1 |
IEC 60947-7-1 |
IEC 60947-7-1 |
IEC 60947-7-1 |
IEC 60947-7-1 |