Home Categories Send inquiry

UPT-2.5PE/L/L Triple Layer Low Voltage Power Insulated Spring Cage high quality terminal block

Advantage

The Push-in direct connection technology make the insertion forces reduced by up to 50 percent and tool-free wiring, enable the conductors to be inserted easily and directly. Made from engineering flame retardants nylon PA66 with brass screw metal. Made from engineering flame retardants nylon PA66 with brass screw metal. ●The Push-in connection terminal blocks are characterized by easy and tool-free wiring of conductors with ferrules or solid conductors. ●The compact design and front connection enable wiring in a confined space. ●In addition to the testing facility in the double function shaft, all terminal blocks provide an additional test connection. ●With universal foot which can be installed on Din Rail NS 35. ●It can connect two conductors with ease, even large conductor cross sections are not a problem. ●Electric potential distribution can use fixed bridges in the terminal center. ●All types of accessories: End cover, End Stopper, Partition plate, marker trip, fixed bridge, insertion bridge, etc.

Details parameters

Product Image
Product number UPT-2.5/2-2PE UPT-2.5/2PE UPT-2.5/1-2PE UPT-2.5PE/L/L UPT-2.5PE/L/N
product type Rail wiring distribution block Rail wiring distribution block Rail wiring distribution block Rail wiring distribution block Rail wiring distribution block
Mechanical structure Push-in spring connection Push-in spring connection Push-in spring connection Push-in spring connection Push-in spring connection
layers 1 2 1 3 3
Electric potential 1 1 1 1 1
connection volume 4 4 3 6 6
Rated cross section 2.5 mm2 2.5 mm2 2.5 mm2 2.5 mm2 2.5 mm2
Rated current
Rated voltage
open side panel Yes Yes Yes Yes Yes
grounding feet no no no no no
other The connecting rail needs to install the rail foot F-NS35 The connecting rail needs to install the rail foot F-NS35 The connecting rail needs to install the rail foot F-NS35 The connecting rail needs to install the rail foot F-NS35 The connecting rail needs to install the rail foot F-NS35
Application field Widely used in electrical connection, industrial Widely used in electrical connection, industrial Widely used in electrical connection, industrial Widely used in electrical connection, industrial Widely used in electrical connection, industrial
color (green)、(yellow)、customizable (green)、(yellow)、customizable (green)、(yellow)、customizable (green)、(yellow)、customizable (green)、(yellow)、customizable
Wiring data
line contact
thickness 5.2mm 5.2mm 5.2mm 5.2mm 5.2mm
width 72.4mm 68.4mm 60.4mm 102.2mm 102.2mm
high 35.3mm 46.1mm 35.3mm 56.45mm 56.45mm
NS35/7.5 high 36.8 mm 47.6mm 36.8 mm 58mm 58mm
NS35/15 high
NS15/5.5 high
Flame retardant grade, in line with UL94 V0 V0 V0 V0 V0
Insulation Materials PA PA PA PA PA
Insulation material group I I I I I
  standard test IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1
Rated voltage(III/3) 500V 500V
Rated current(III/3) 20A 20A
Rated surge voltage 8kv 8kv 8kv 8kv 8kv
Overvoltage class III III III III III
pollution level 3 3 3 3 3
Surge Voltage Test Results Passed the test Passed the test Passed the test Passed the test Passed the test
Power frequency withstand voltage test results Passed the test Passed the test Passed the test Passed the test Passed the test
Temperature rise test results Passed the test Passed the test Passed the test Passed the test Passed the test
Ambient temperature (operating) -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.)
Ambient temperature (storage/transport) -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C)
Ambient temperature (assembled) -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C
Ambient temperature (execution) -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C -5 °C — 70 °C
Relative Humidity (Storage/Transportation) 30 % — 70 % 30 % — 70 % 30 % — 70 % 30 % — 70 % 30 % — 70 %
RoHS No excessive harmful substances No excessive harmful substances No excessive harmful substances No excessive harmful substances No excessive harmful substances
Connections are standard IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1 IEC 60947-7-1