Advantages of JUT15-6-2.5 Series
Can be installed vertically or parallel to DIN rail, saving up to 50% of rail space.
It can be installed by DIN rail, direct installation or adhesive installation, which is more flexible to use.
Time-saving wire connection thanks to tool-free push-in connection technology.
Modules can be installed immediately without manual bridging, saving up to 80% of time.
Different colors, the wiring is more clear.
JUT15-6-2.5 Series
Product number |
JUT15-6-4x2.5-F |
JUT15-6-6x2.5-F |
JUT15-6-10x2.5-F |
JUT15-6-12x2.5-F |
JUT15-6-18x2.5-F |
product type |
Plug-in terminal block |
Plug-in terminal block |
Plug-in terminal block |
Plug-in terminal block |
Plug-in terminal block |
Mechanical structure |
Push-in spring connection |
Push-in spring connection |
Push-in spring connection |
Push-in spring connection |
Push-in spring connection |
layers |
1 |
1 |
1 |
1 |
1 |
Electric Potential |
1 |
1 |
1 |
1 |
1 |
connection volume |
5 |
7 |
11 |
13 |
19 |
Rated cross section |
2.5 mm2 |
2.5 mm2 |
2.5mm2 |
2.5mm2 |
2.5mm2 |
Rated current |
24A |
24A |
24A |
24A |
24A |
Rated voltage |
690V |
690V |
690V |
690V |
690V |
open side panel |
no |
no |
no |
no |
no |
grounding feet |
no |
no |
no |
no |
no |
other |
The connecting rail needs to install the rail foot F-NS35 |
Application field |
It is generally used for related supporting facilities such as electric connection industries and industries. |
color |
Gray, dark gray, green, yellow, cream, orange, black, red, blue, white, purple, brown, customisable |
Wiring Data
load contact |
Stripping length |
8mm —10mm |
8mm —10mm |
8mm —10mm |
8mm —10mm |
8mm —10mm |
Rigid Conductor Cross Section |
0.14mm² — 4mm² |
0.14mm² — 4mm² |
0.14mm² — 4mm² |
0.14mm² — 4mm² |
0.14mm² — 4mm² |
Flexible conductor cross section |
0.14mm² — 2.5mm² |
0.14mm² — 2.5mm² |
0.14mm² — 2.5mm² |
0.14mm² — 2.5mm² |
0.14mm² — 2.5mm² |
Rigid Conductor Cross Section AWG |
26-12 |
26-12 |
26-12 |
26-12 |
26-12 |
Flexible Conductor Cross Section AWG |
26-14 |
26-14 |
26-14 |
26-14 |
26-14 |
line contact |
Stripping length |
10mm —12mm |
10mm —12mm |
10mm —12mm |
10mm —12mm |
10mm —12mm |
Rigid Conductor Cross Section |
0.5mm² — 10mm² |
0.5mm² — 10mm² |
0.5mm² — 10mm² |
0.5mm² — 10mm² |
0.5mm² — 10mm² |
Flexible conductor cross section |
0.5mm² — 10mm² |
0.5mm² — 10mm² |
0.5mm² — 10mm² |
0.5mm² — 10mm² |
0.5mm² — 10mm² |
Rigid Conductor Cross Section AWG |
20-8 |
20-8 |
20-8 |
20-8 |
20-8 |
Flexible Conductor Cross Section AWG |
20-10 |
20-10 |
20-10 |
20-10 |
20-10 |
Size (this is the dimension of the JUT15F carrying rail foot F-NS35 installed on the rail)
thickness |
24mm |
29.2mm |
39.6mm |
44.8mm |
60.4mm |
width |
45.5mm |
45.5mm |
45.5mm |
45.5mm |
45.5mm |
Height |
21.7mm |
21.7mm |
21.7mm |
21.7mm |
21.7mm |
NS35/7.5 high |
31.1mm |
31.1mm |
31.1mm |
31.1mm |
31.1mm |
NS35/15 high |
38.6mm |
38.6mm |
38.6mm |
38.6mm |
38.6mm |
NS15/5.5 high |
|
|
|
|
|
Material Properties
Flame retardant grade, in line with UL94 |
V0 |
V0 |
V0 |
V0 |
V0 |
Insulation Materials |
PA |
PA |
PA |
PA |
PA |
Insulation material group |
I |
I |
I |
I |
I |
IEC Electrical Parameters
standard test |
IEC 60947-7-1 |
IEC 60947-7-1 |
IEC 60947-7-1 |
IEC 60947-7-1 |
IEC 60947-7-1 |
Rated voltage(III/3) |
690V |
690V |
690V |
690V |
690V |
Rated current(III/3) |
24A |
24A |
24A |
24A |
24A |
Rated surge voltage |
8kv |
8kv |
8kv |
8kv |
8kv |
Overvoltage class |
III |
III |
III |
III |
III |
pollution level |
3 |
3 |
3 |
3 |
3 |
Electrical Performance Test
Surge Voltage Test Results |
Passed the test |
Passed the test |
Passed the test |
Passed the test |
Passed the test |
Power frequency withstand voltage test results |
Passed the test |
Passed the test |
Passed the test |
Passed the test |
Passed the test |
Temperature rise test results |
Passed the test |
Passed the test |
Passed the test |
Passed the test |
Passed the test |
Environmental Conditions
Ambient temperature (operating) |
-60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) |
Ambient temperature (storage/transport) |
-25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) |
Ambient temperature (assembled) |
-5 °C — 70 °C |
-5 °C — 70 °C |
-5 °C — 70 °C |
-5 °C — 70 °C |
-5 °C — 70 °C |
Ambient temperature (execution) |
-5 °C — 70 °C |
-5 °C — 70 °C |
-5 °C — 70 °C |
-5 °C — 70 °C |
-5 °C — 70 °C |
Relative Humidity (Storage/Transportation) |
30 % — 70 % |
30 % — 70 % |
30 % — 70 % |
30 % — 70 % |
30 % — 70 % |
Environmental Friendly
RoHS |
No excessive harmful substances |
Standards and Specifications
Connections are standard |
IEC 60947-7-1 |
IEC 60947-7-1 |
IEC 60947-7-1 |
IEC 60947-7-1 |
IEC 60947-7-1 |
JUT15-6-6x2.5-F
JUT15-6-10x2.5-F
JUT15-6-12x2.5-F
JUT15-6-18x2.5-F