Product Image | ||||||
Product number | UPTC-4RD | UPTC-4RD/LA250 | UPT-4RD/LED24 | UPT-4RD/LED60 | UPT-4RD/LA250 | UPT-4RD/C/LED60 |
product type | Rail wiring distribution block | Rail wiring distribution block | Rail wiring distribution block | Rail wiring distribution block | Rail wiring distribution block | Rail wiring distribution block |
Mechanical structure | Push-in spring connection | Push-in spring connection | Push-in spring connection | Push-in spring connection | Push-in spring connection | Push-in spring connection |
layers | 1 | 1 | 1 | 1 | 1 | 1 |
Electric potential | 1 | 1 | 1 | 1 | 1 | 1 |
connection volume | 2 | 2 | 2 | 2 | 2 | 2 |
Rated cross section | 4 mm2 | 4 mm2 | 4 mm2 | 4 mm2 | 4 mm2 | 4 mm2 |
Rated current | 6.3A | 6.3A | 6.3A | 6.3A | 6.3A | 6.3A |
Rated voltage | 400V | 250V | 24V | 60V | 250V | 60V |
open side panel | Yes | Yes | Yes | Yes | Yes | Yes |
grounding feet | no | no | no | no | no | no |
other | The connecting rail needs to install the rail foot F-NS35 | The connecting rail needs to install the rail foot F-NS35 | The connecting rail needs to install the rail foot F-NS35 | The connecting rail needs to install the rail foot F-NS35 | The connecting rail needs to install the rail foot F-NS35 | The connecting rail needs to install the rail foot F-NS35 |
Application field | Widely used in electrical connection, industrial | Widely used in electrical connection, industrial | Widely used in electrical connection, industrial | Widely used in electrical connection, industrial | Widely used in electrical connection, industrial | Widely used in electrical connection, industrial |
color | (orange)、(black)、customizable | (orange)、(black)、customizable | (orange)、(black)、customizable | (orange)、(black)、customizable | (orange)、(black)、customizable | (orange)、(black)、customizable |
Stripping length | 8mm — 10mm | 8mm — 10mm | 8mm — 10mm | 8mm — 10mm | 8mm — 10mm | 8mm — 10mm |
Rigid Conductor Cross Section | 0.2mm² — 6mm² | 0.2mm² — 6mm² | 0.2mm² — 6mm² | 0.2mm² — 6mm² | 0.2mm² — 6mm² | 0.2mm² — 6mm² |
Flexible conductor cross section | 0.2mm² — 4mm² | 0.2mm² — 4mm² | 0.2mm² — 6mm² | 0.2mm² — 6mm² | 0.2mm² — 6mm² | 0.2mm² — 6mm² |
Rigid Conductor Cross Section AWG | 24-10 | 24-10 | 24-10 | 24-10 | 24-10 | 24-10 |
Flexible Conductor Cross Section AWG | 24-10 | 24-10 | 24-10 | 24-10 | 24-10 | 24-10 |
thickness | 8.2mm | 8.2mm | 6.2mm | 6.2mm | 6.2mm | 8.2mm |
width | 67.8mm | 67.8mm | 55.8mm | 55.8mm | 55.8mm | 67.8mm |
high | 41.5mm | 41.5mm | 63.34mm | 63.34mm | 63.34mm | 41.5mm |
NS35/7.5 high | 43mm | 43mm | 64.8mm | 64.8mm | 64.8mm | 43mm |
NS35/15 high | ||||||
NS15/5.5 high |
Flame retardant grade, in line with UL94 | V0 | V0 | V0 | V0 | V0 | V0 |
Insulation Materials | PA | PA | PA | PA | PA | PA |
Insulation material group | I | I | I | I | I | I |
standard test | IEC 60947-7-1 | IEC 60947-7-1 | IEC 60947-7-1 | IEC 60947-7-1 | IEC 60947-7-1 | IEC 60947-7-1 |
Rated voltage(III/3) | 500V | 250V | 24V | 60V | 250V | 60V |
Rated current(III/3) | 6.3A | 6.3A | 6.3A | 6.3A | 6.3A | 6.3A |
Rated surge voltage | 8kv | 8kv | 8kv | 8kv | 8kv | 8kv |
Overvoltage class | III | III | III | III | III | III |
pollution level | 3 | 3 | 3 | 3 | 3 | 3 |
Surge Voltage Test Results | Passed the test | Passed the test | Passed the test | Passed the test | Passed the test | Passed the test |
Power frequency withstand voltage test results | Passed the test | Passed the test | Passed the test | Passed the test | Passed the test | Passed the test |
Temperature rise test results | Passed the test | Passed the test | Passed the test | Passed the test | Passed the test | Passed the test |
Ambient temperature (operating) | -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) | -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) | -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) | -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) | -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) | -60 °C — 105 °C (Maximum short-term operating temperature, electrical characteristics are relative to temperature.) |
Ambient temperature (storage/transport) | -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) | -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) | -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) | -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) | -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) | -25 °C — 60 °C (short term (up to 24 hours), -60 °C to +70 °C) |
Ambient temperature (assembled) | -5 °C — 70 °C | -5 °C — 70 °C | -5 °C — 70 °C | -5 °C — 70 °C | -5 °C — 70 °C | -5 °C — 70 °C |
Ambient temperature (execution) | -5 °C — 70 °C | -5 °C — 70 °C | -5 °C — 70 °C | -5 °C — 70 °C | -5 °C — 70 °C | -5 °C — 70 °C |
Relative Humidity (Storage/Transportation) | 30 % — 70 % | 30 % — 70 % | 30 % — 70 % | 30 % — 70 % | 30 % — 70 % | 30 % — 70 % |
RoHS | No excessive harmful substances | No excessive harmful substances | No excessive harmful substances | No excessive harmful substances | No excessive harmful substances | No excessive harmful substances |
Connections are standard | IEC 60947-7-1 | IEC 60947-7-1 | IEC 60947-7-1 | IEC 60947-7-1 | IEC 60947-7-1 | IEC 60947-7-1 |