Home Categories Send inquiry

UUK-4/2-2 4mm Two In Tow Out Feed Through Screw Connector Terminal

Advantage

Industrial Distribution Terminal Blocks Screw type Closed bolt leading hole will not only facilitate operation of screwdrivers, also prevent the bolt from dropping out; Electric potential distribution is realized by either connecting central adaptor to the center of terminal or inserting a side adaptor to the cone jack; General auxiliaries,such as end plate,segment spacer, and spacer, are attached for terminal with multiple sections; The insulating shell is made if imported engineering plastic polyamides(Nylon)66,which is of high mechanical intensity, good electrical conductivity, and super flexibility; Two ends on the top with white marking system to realize uniformed sign. •  500V •  Good workmanship •  Stable performance •  Easy to install •  Segment test terminal latest structure •  Rich accessories to meet the needs of different occasions
PRODUCT DETAIL DATA
Product properties UUK-4/2-2--GY UUK-4/2-2--PE
Wiring Diagram    
Product Classification Straight-through terminal block, Two-in Two-out Ground terminal block & Two-in Two-out
Product Type Screw Type Terminal Block Screw Type Terminal Block
Product Series UUK UUK
Connect Number 4 4
Industry Power Industry Factory engineering process control Mechanical Engineering Railway industry Power Industry Factory engineering process control Mechanical Engineering Railway industry
Potential 1 1
Wiring data UUK-4/2-2--GY UUK-4/2-2--PE
Strip Length 9 9
AWG 24  ~  10 24  ~  10
Rigid conductor cross section  0.2 mm²  ~ 6 mm²  0.2 mm²  ~ 6 mm²
Flexible conductor cross section  0.2 mm²  ~ 6 mm²  0.2 mm²  ~ 6 mm²
Minimum wiring capacity of single wire 0.2 0.2
Maximum wiring capacity of single strand wire 6 6
Minimum wiring capacity of multi-strand wires 0.2 0.2
Maximum wiring capacity of multi-strand wires 6 6
Incoming line direction Side Cable Entry Side Cable Entry
Width(mm) 6.2 6.2
Height(mm) 65.4 65.4
Deep (mm) 46.9 46.9
NS 35/7.5 47.5 47.5
NS35/15 55 55
IEC parameters UUK-4/2-2--GY UUK-4/2-2--PE
Rated impulse withstand voltage 6kV 6kV
Rated voltage 500
Rated current 32
UL parameters UUK-4/2-2--GY UUK-4/2-2--PE
Rated voltage
Rated current
Material specifications UUK-4/2-2--GY UUK-4/2-2--PE
Color Grey Yellow & Green
Flammability rating V0 V0
Pollution level 3 3
Insulation material group I I
Insulation Materials PA66 PA66
Standards and Norms UUK-4/2-2--GY UUK-4/2-2--PE
Connections comply with standards IEC 60947-7-1 GB14048.7.1 IEC 60947-7-2 GB14048.7.2